Define nominal and measured values

The nominal thickness belongs in the purchase specification. Keep the measured mean, minimum, maximum and individual readings in the inspection record, with units and the sample identity. Agree whether any tolerance applies to individual readings, a mean, or both.

Illustrative measurement recordValue
Nominal thickness20 μm
Three example readings19.4, 20.1 and 20.5 μm
Mean20.0 μm
Observed range19.4–20.5 μm
AcceptanceApply the agreed sampling and tolerance rules. The example sets neither.

Plan width and length samples

Sketch an unwind direction and mark locations across the web from one edge through the center to the other edge. Choose repeated rows along the roll length and assign a location ID to each reading. Agree roll count, point count, any edge offsets and how far to sample into the roll before inspecting a lot.

Keep the edge results visible. If measurements at deliberate edge positions follow special rules, label the points and the rule so the mean can be reproduced.

Agree measurement conditions

Record the method and revision, equipment ID, calibration status, conditioning and any thickness gauge contact settings required by the chosen procedure. Use a specimen handling procedure that avoids extra tension, wrinkles or folded layers at the measurement point.

ASTM D6988 is a guide to thickness measurement of plastic film test specimens. Set the purchasing sampling plan and lot criteria separately, and have the laboratory confirm that the selected method suits the measurement.

Set lot acceptance

  1. Agree limits, the affected result type, lot definition and who can release stock.
  2. Record every out-of-limit point and check whether the instrument or method was used as agreed.
  3. Hold the identified material while following the agreed retest and escalation process.
  4. Keep original and retest readings with the documented lot decision.

For example, one low point could trigger a defined retest or an immediate hold depending on the purchase rule. Preserve its position, condition and roll ID in either case.