Identify what each document covers
| Document | What to verify |
|---|---|
| Technical data sheet (TDS) | The grade described and which values are typical, declared or specified acceptance limits. |
| Certificate of analysis (COA) | The issuing party, named lot, measured or certified fields, and reference limits if shown. |
| Sample test report | The submitted specimen, testing organization, method, conditions and results for that specimen. |
Use the document issuer and scope to determine how much independent evidence each record provides.
Trace the quote, roll and report
Compare the SKU on the quote with the roll label and the report’s sample description. Where a COA is required, check that the delivered lot matches the lot listed. Record any alternate name or code and request a written cross-reference before using the document for approval.
Example: A TDS for the offered grade can describe its typical properties. If the arrived lot has a different number from the COA, request the record for the arrived lot.
Read the test conditions and coverage
Check method revision, specimen direction, thickness, units, conditioning and the number or scope of samples where reported. Ask about missing fields that could change interpretation. For a sample report, clarify how that specimen was collected before deciding what it says about an order.
Keep the approved version with the order
Save the original document with its grade, date and revision and retain the link to the approved roll and purchase specification. For a revised TDS or COA format, check whether it changes an acceptance criterion, a method or only the document layout. Record the review before applying it to a new order.